Canadian buyer guide

Gausium Scrubber 50 vs. Tennant T7AMR: which fits your Canadian facility?

Which workflow should drive your shortlist?

Scrubber 50 is a useful shortlist candidate for tighter, turn-heavy routes; T7AMR offers a wider path and larger tanks for open-floor work. Choose using accessible floor area and the cleaning window, not gross building size. Elevator use, winter entry soil and remaining manual work can change the decision.

  • A school corridor or retail route with frequent turns can favour the smaller machine, provided the demonstrated clearance works with doors, carts and people present.
  • An arena concourse, convention centre or open warehouse may make better use of the T7AMR path and tank capacity. Count the accessible hard-floor area, not the total building footprint.
  • For elevator travel, verify cabin geometry, permitted load including water, door timing and the integration scope. A machine fitting in the cabin does not establish unattended elevator operation.

How do the published specifications compare?

Scrubber 50 offers 30-litre clean-water capacity and a 460 mm disc path; T7AMR offers 110 litres and a 650 mm path. The productivity figures below use different practical and theoretical bases. They do not establish a speed ratio or prove how much clean floor either machine delivers at your site.

On smaller screens, swipe across the table to compare every model.

Manufacturer reference specifications · checked 24 November 2026
SpecificationGausium Scrubber 50Tennant T7AMR
Cleaning path460 mm disc; 406 mm roller650 mm (26 in)
Clean / recovery tanks30 / 24 L110 / 110 L
Published productivity500–1,300 m²/h practical2,660 m²/h autonomous theoretical
Scrubbing runtimeAbout 3 hUp to 4 h lead-acid; up to 6.5 h lithium-ion
Other cleaning runtimeDust mopping: 8 h disc / 6 h rollerConfirm with supplier
Machine mass157 kg disc / 148 kg roller492 kg with standard battery, tanks empty
Dimensions810 × 700 × 1,070 mm1,645 mm long; 850 mm squeegee width; 1,450 mm high with light
Passage / turning800 mm minimum passage; 1,100 mm U-turnConfirm with supplier for the autonomous route
Navigation / configurationConfirm sensors and docking options in quoteBrainOS; confirm battery and accessory package

Practical and theoretical productivity use different test assumptions: these figures are not a controlled head-to-head test.

Tennant publishes a 650 mm / 26 in path; do not convert the rounded inch designation into a different metric specification. Gausium disc and roller figures describe different configurations.

Sources: Gausium Scrubber 50 specifications · Tennant product guide: autonomous and manual productivity · Tennant T7AMR operator manual: dimensions and mass · Tennant T7AMR product specifications

What needs checking at a Canadian site?

Check the proposed equipment and its supporting infrastructure together. Canadian deployment decisions include the actual route or work envelope, electrical acceptance, staff procedures and service responsibility. Treat the following as questions for the facility, supplier and qualified installer; this guide does not certify a product or replace a site assessment.

  • Winter entry areas: test actual salt residue and grit, pre-sweeping requirements, detergent compatibility, recovery and the number of passes needed to leave a safe floor.
  • Water conservation: ask how recycling, filter cleaning and refill arrangements affect water use and staff time. Confirm Scrubber 50 filtration equipment and maintenance for the quoted version.
  • Docking: identify water supply, drainage, electrical approval, protected parking and who will maintain the docking area. Confirm whether installation is included.
  • Service: request consumable lead times, battery replacement terms and the responsible Canadian service provider. Do not assume a loaner or local parts inventory is included.

Health Canada’s electrical product guidance explains recognised Canadian certification marks. Confirm the applicable industrial and provincial requirements for your installation. See Kiza’s verification and deployment approach.

How should purchase, RaaS and pilot costs be compared?

Ask for a CAD proposal covering the complete deployment, then compare arrangements over the same operating period. Equipment price alone omits integration, training and ongoing work. Kiza treats pricing, rental availability and financing terms as custom-quoted items; no published estimate here implies stock, credit approval or a guaranteed service commitment.

  • Purchase: separate equipment, freight, commissioning, software, accessories, training and taxes. Request a maintenance and consumables budget.
  • RaaS: check ownership, minimum term, included support, usage limits, annual changes and early termination. Any conversion-to-purchase option must be written into the proposal.
  • Pilot rental: define duration, installation, acceptance tests, operator responsibilities and collection or return charges. Confirm equipment availability before scheduling.
  • Tax treatment: ask your CPA about CCA eligibility and the treatment of the actual purchase, lease or service contract. Do not base approval on an assumed deduction.

Compare purchase, financing and RaaS · Scope a pilot rental · Review service plans

What should a pilot prove before you commit?

A useful pilot proves an operating result that your team can repeat. Agree the baseline, acceptance criteria and staff responsibilities before equipment arrives. Record interruptions and manual work as carefully as completed tasks, then review the outcome with the people who will operate and maintain the system after handover.

  1. Map one repeatable route containing both open floor and the tightest operating turns. Record excluded areas and manual edge work.
  2. Measure accepted clean area per staffed shift, refills, recovery disposal, manual interventions, drying quality and remaining manual labour.
  3. Run a representative winter-soil trial if that is a buying requirement. A clean summer demonstration cannot establish salt and slush performance.

Send your task, facility constraints and preferred timeline through our guided project enquiry. A shortlist is the start of technical verification, not a commitment to a particular model.

Which sources and related guides support this comparison?

Manufacturer pages and manuals provide the reference specifications; Kiza’s workflow recommendations are an editorial assessment of those figures and the procurement questions above. Sources can change by region and revision. Confirm the supplied model in writing, and use the linked application pages to prepare a more specific project brief.

Manufacturer references do not imply an authorised distribution agreement, independent performance testing or guaranteed Canadian availability.

What else do Canadian buyers ask?

These answers address common decisions before a quotation or pilot. They distinguish a published specification from a confirmed site outcome and identify matters that need written supplier confirmation. Use them with the comparison table, rather than as a substitute for the operating trial, configuration review and service agreement for your facility.

Is Tennant’s 45,760 ft²/h figure an autonomous cleaning rate?

No. Tennant’s product guide separates 45,760 ft²/h manual theoretical coverage from 28,600 ft²/h autonomous theoretical coverage. Neither is a measured result for your building. Compare accepted clean area after turns, obstacles, refills and rework.

Is a 70,000 ft² building automatically a T7AMR application?

No. Building area alone is not a selection rule. Narrow routes, floor transitions, storage density, working hours and the actual cleanable area can matter more than gross floor area. Test the route and the available cleaning window.

Which machine is better for Canadian winter salt?

Neither has a universal advantage without a trial. Include the actual floor finish, grit removal, salt residue, approved chemical and drying requirements in the pilot. Ask who handles slush accumulation and manual entrance work between robot passes.

Does the quoted robot have Canadian electrical approval?

Confirm with supplier. Obtain evidence for the exact robot, charger and dock configuration, then check acceptance with the relevant electrical authority or qualified installer. A brand name or overseas conformity mark alone is not the answer.

Can we compare RaaS with outright purchase?

Yes, request both for the same equipment and deployment scope. Compare CAD payments, contract length, maintenance, consumables, software, battery cover and end-of-term terms. Availability and any purchase conversion must be confirmed in writing.